Fuel Storage Safety Checklist
Farm fuel tanks hold large amounts of energy, and leaks reach soil and water before anyone notices. This checklist covers where a tank sits, how it is grounded and contained, how it is labeled, and how to check it on a routine.
Why it matters
A fuel release is dangerous, costly and often reportable. Rules for tank size, distance from buildings and wells, and containment differ by state and county, so call your state environmental agency, your fire marshal or your extension office before installing or moving a tank.
Step by step
- Site tanks on level, stable ground away from buildings, wells, drains and ditches, at distances confirmed with your fire marshal and state agency.
- Place the tank in secondary containment sized under your local rule, with a cover or drain plan so rainwater does not fill the space.
- Ground and bond the tank, nozzle and any transfer container, and fill portable cans on the ground, never on a truck bed liner.
- Label each tank with product, capacity and a no-smoking and no-ignition warning, and keep it free of weeds and dry debris.
- Inspect fittings, hoses, gaskets, vents and the tank bottom monthly, looking for stains, drips, rust, swelling or dead vegetation.
- Reconcile deliveries against dispensing monthly, and investigate any unexplained loss before it becomes a larger release.
Worked example
Illustrative: A 500-gallon tank sits in a basin sized to hold 110 percent of tank volume under a local rule. Required volume is 500 x 1.10 = 550 gallons. A basin 8 ft x 6 ft x 1.5 ft holds 72 cubic feet, or 72 x 7.48 = 538.6 gallons, which is short. At 1.6 ft deep it holds 76.8 x 7.48 = 574.5 gallons, enough, though rain space is still needed.
Printable worksheet: fuel tank monthly check
- Tank ID, product and capacity: ____________________
- Check date and inspector: ______ / ______
- Containment length x width x depth (ft): ______ x ______ x ______
- Basin volume = cubic ft x 7.48: ______ gallons ; required: ______
- Stains, drips, rust or damaged hose found: ______
- Grounding cable and labels in place: yes / no
- Delivered ______ gal minus dispensed ______ gal = ______ gal on hand
Common mistakes
- Letting rainwater fill the containment and then pumping it onto the ground without checking for fuel sheen.
- Filling a can in a truck bed, where static charge can build because the container is not grounded to the earth.
- Putting the tank beside a wellhead or drain for convenience and discovering the setback problem after a release.
- Writing off a monthly loss of a few gallons as evaporation when it may be a hidden leak.
Frequently asked questions
How large must containment be?
Rules vary by state, county and tank size, and the 110 percent figure here is only an illustration. Ask your state environmental agency or fire marshal what applies, and write the answer on the tank record.
What do I do if fuel spills?
Stop the source if safe, eliminate ignition sources, keep people away, contain the liquid with absorbent, and call emergency services for a fire or injury. Ask your state agency about reporting requirements and disposal.
Can I store fuel in the shop?
Only small amounts in approved safety cans or cabinets, away from ignition and exits, under local rules. Bulk fuel belongs outside in approved tanks. Ask your fire marshal or insurer before you store any more.
Official sources
- NFPA: National Fire Protection Association
- OSHA: Occupational Safety and Health Administration
- eXtension: Cooperative Extension resources
Educational only. Follow the equipment manual, label or SDS and OSHA rules. State shop resources.